Hot dip galvanizing has been used for more than 150 years, and its principle has not changed so far. The steel structure should be fully immersed in zinc at one time to achieve uniform galvanized film structure. If it is too long or too wide to be dipped twice, the zinc layer at the joint will appear rough, too thick and so on. In addition, if the single weight of steel structure is too heavy, it will make its operation difficult if it exceeds the load of galvanizing equipment. Therefore, the communication with the hot dip galvanizing factory in advance.
Usually, there are three kinds of metal corrosion: physical corrosion, chemical corrosion, electrochemical corrosion, corrosion in addition to the chemical properties and organizational structure of the metal itself, but also related to the surrounding medium, such as wet environment is easier to rust than dry environment, more impurities than impurities less easy corrosion, high temperature conditions than low temperature conditions easy corrosion. After understanding these, we can effectively prevent the customized corrosion of hexagonal guardrail and extend the service life of the product.
National standards on the use of wire mesh standards have certain requirements, diameter and mesh size matching use, rather than simply diameter, on the plaster layer to use the mesh should not be greater than 20×20, diameter is not easy to be less than 1mm, just choose diameter is not much meaning, choose 40×40×0.9 and choose 10×10×0.6 wire mesh, Which is better? I’m afraid it’s 10 by 10 by 0.6.
It’s not clear why friends would want to use building nets for floor heating. What is its advantage in the floor heating project, the role of steel wire mesh is convenient for construction. Building mesh can better fix the pipe, conducive to the construction of the floor, improve efficiency. Anti-cracking function. The building network can improve the bearing capacity of the foundation of the insulation board, the thicker the diameter of the building steel wire, the greater the bearing capacity, effectively prevent the appearance of cracks and cracks of steel wire mesh can improve the thermal shrinkage and shrinkage of cement, strengthen the tensile strength of cement, improve the quality of the heating project.
Electro galvanizing shaft wire direct is in the electroplating tank through the current unidirectional zinc gradually plated on the metal surface, production speed is slow, uniform coating, thin thickness, usually only 3-15 microns, bright appearance, poor corrosion resistance, generally a few months will rust. Compared with hot dip galvanizing, electric galvanizing has lower production cost. The difference between cold galvanizing and hot galvanizing: the difference between cold galvanizing and hot galvanizing is that the amount of zinc is different. They can be identified from the color. The color of cold galvanizing is shiny silver white with yellow. Hot dip galvanized shiny hair white.
2, performance characteristics. Zinc coating is thick, fine crystallization, uniform and no pores, good corrosion resistance; Is pure, the zinc plating layer in acid, alkali corrosion slower, such as fog Eng effectively protect tight sand-fixation matrix, the galvanized layer formed after chromate passivation, color white, army green, beautiful and easy, have certain adornment sex, because the galvanized layer has good ductility, and therefore can be rushed, rolling, cold bending and forming and not damage the coating.
The life of the “wire”, is actually “low carbon steel wire”, carbon content in less than 0.2%. The surface is usually coated with zinc plating because it is easy to rust. Under atmospheric conditions, the galvanized layer will not rust before most of the fall off, relatively soft. The life of the “steel wire”, is carbon content in about 0.6% of the “carbon steel wire”, or carbon content in about 0.8% of the “high carbon steel wire”, they have enough hardness and elasticity after appropriate heat treatment, high strength. Uses such as winding ordinary spring and so on.