Paint on the galvanized layer, the bonding force between each other has a great relationship with the baking temperature of the paint, and alkyd paint is coated after galvanized, and the adhesion is not a problem. After galvanized to do amino paint, paint adhesion is not very good. Do two bottom two surface, adhesion is good, if the two bottom two surface changed to two bottom three surface, that is, more paint, more baked once, again test adhesion is very bad, bad enough to tear the paint from the galvanized layer.
Operating procedures: When using cold galvanized wire, all tools and stacked objects obstructing activities should be removed from the work site and equipment. When pickling, put the wire into the cylinder slowly to prevent acid splashing on the body. When adding acid, it is necessary to pour the acid into the water slowly. It is forbidden to pour the water into the acid to prevent the acid from splashing out. Wear protective glasses when working. Do not push or beat cold galvanized wire and other articles when handling them.
Greenhouse special electroplating process iron wire blackening solution:
Many pet cages are designed with a small box in the base, so that pets can clean up when they poop, but also convenient for pets’ health. For example, if there is no excreta box, pet excreta will be on the ground, which is quite unhealthy. If you have a box, it’s easy to take the box out and wash the trash away so it doesn’t get all over the place, so it’s more hygienic.
(1) Easy to use, only the mesh surface tile wall, building cement can be used;
The use of welding network is very wide, but also used in different industries, different places, many times the name is because of the use or use of the name, so the various uses of the welding network, destined to name a variety of different. Can be called row welding net, or zinc plating welding net or galvanized welding net. And then there’s the external insulation wire, just for insulation, usually on the outside of the wall, to reduce heat loss.
At present, there are two main kinds of electric galvanized wire products, hot dip galvanized wire and electric galvanized wire. The difference is that the way of galvanizing is different, and the quality of the products is different. Hot dip galvanized wire zinc layer thick, corrosion resistance is stronger, but correspondingly, the price is high. Galvanized wire zinc coating thin, corrosion resistance is poor, but the price is low.
The quality of hot-dip galvanized barbed wire is only good in the surface of the wire attached to the galvanized layer, and with the chemical reaction, the surface of the zinc layer will gradually lose effect because of the oxidation reaction, this situation is more prominent in the humid area of the environment. And because after all, it is rusty iron wire, so the quality of hot-dip galvanized barbed rope is certainly not up to the level of stainless steel barbed rope.
For the specification of galvanized wire, the galvanized wire produced by our factory can range from No.8 to No.22, which refers to the BWG standard, that is, from about 4mm to 0.7mm, which can basically cover the type required by the customer. As for the raw material of galvanized wire, normally, we use Q195 mild steel, and some factories will also use SAE1006 or SAE1008. The following is the zinc coating, for galvanized wire, this is very important, the general zinc coating is about 50g/m2 to 80g/m2, some customers need high zinc galvanized wire, zinc coating can reach 200g/m2 to 360g/m2. The tensile strength of galvanized wire is usually 350n/m2 to 800n/m2. Then there is the packaging specification of galvanized wire. The specifications of small rolls of galvanized wire are 50kg/ roll, 100kg/ roll and 200kg/ roll. Of course, there are large rolls of galvanized wire, the weight can reach 300kg/ roll or 800kg/ roll.
In order to pack and bundle galvanized wire on the surface of the deposit layer to remove the surface film, surface inclusion and other defects can be found and treated by conventional technology; Excess foam is caused by soaps and saponable fatty surfactants being brought into the tank. Moderate foam formation rates may be harmless. Small homogeneous particles of large denier present in the tank can stabilize the foam layer. To remove surface active substances by matting with activated carbon. Or filtration to make the foam less stable, which are effective measures; Other measures should also be taken to reduce the intake of surfactant. The electroplating speed can be significantly reduced by the introduction of organic matter. Although the chemical formula is conducive to a high deposition rate, the coating thickness cannot meet the requirements after the organic matter is loaded, so activated carbon can be used to treat the tank.
Hongyu twist flower hexagonal mesh factory is the selection of low carbon steel silk woven, mesh structure he has the characteristics of corrosion resistance, high strength and ductility. Steel wire diameter up to 2.0mm-4.0mm, steel wire appearance is usually selected hot dip galvanized maintenance, galvanized maintenance layer thickness can be made according to customer needs, galvanized maximum can reach 300g/㎡.In the process of composite plating, it is necessary to stir the plating solution to obtain the composite coating in which the particles dispersed in the matrix metal. Stirring methods include mechanical stirring, air stirring, ultrasonic stirring, bath circulation, etc. In the process of production, the acid activation solution can remove the corrosion products and oxide film on the surface of low carbon steel wire without excessive corrosion on the matrix. Galvanized wire can be used zincate galvanized or chloride galvanized and other processes, appropriate additives should be used to obtain the coating required by the standards of low carbon steel wire.
Of course, the quality of any product is also affected by the implementation of the manufacturer’s norms. If it is the manufacturer of electric welding mesh in production, it does not have a high implementation of the norms, or the procedural norms on the production line have decreased, or there is no higher requirements on the production link.1. Choose according to your dog’s size
5, the concentration of plating aid can not be too high, which is a factor that can not be ignored to reduce zinc consumption. The concentration of plating aid should not be too high. The galvanized line must be added with ammonium chloride and zinc chloride according to the data of laboratory analysis, and the specific gravity of the composite solution should be controlled within the range of 50~80g/L. If ammonium chloride or zinc chloride is arbitrarily added without the results of laboratory analysis, it should be criticized and educated, and economic treatment should be given if necessary.
Since galvanized iron wire will rust, we need to pay attention in the process of storage and use, try to store in a dry and ventilated environment, in the process of use to avoid damaging the surface of galvanized iron wire, we can slow down the time of galvanized iron wire rust.
A. When the thickness of the plating is 3-4 mm, the zinc adhesion should be less than 460g/m, that is, the average thickness of the zinc layer is not less than 65 microns.
With other coatings, the opposite is true. Rust builds up immediately and spreads quickly underneath the coating, causing it to peel. The depletion of zinc in the atmosphere is very slow, about 1/17 to 1/18 of the corrosion rate of steel, and is predictable. Its life span far exceeds that of any other coating. The life of the coating depends on the thickness of the coating in a particular environment. And the coating thickness is determined by the thickness of the steel, that is, the thicker the steel is easy to get thicker coating, so the thick steel part of the same steel structure must also get thicker coating, in order to ensure a longer life.