(1) In the painting construction should pay attention to ventilation, moisture-proof, fire prevention. The working environment and painting tools should be kept clean, the pressure of the air pump should be controlled within 0.63MPa, and the safety valve should be checked for failure.
Paint on the galvanized layer, the bonding force between each other has a great relationship with the baking temperature of the paint, and alkyd paint is coated after galvanized, and the adhesion is not a problem. After galvanized to do amino paint, paint adhesion is not very good. Do two bottom two surface, adhesion is good, if the two bottom two surface changed to two bottom three surface, that is, more paint, more baked once, again test adhesion is very bad, bad enough to tear the paint from the galvanized layer.
Pure zinc is more stable in dry air. In moist air or water containing carbon dioxide and oxygen, the surface will generate a layer of basic zinc carbonate based thin film layer, which can delay the corrosion rate of zinc layer. Comparison of corrosion resistance of zinc coating in aqueous solution of acid, alkali and sodium chloride; It is also resistant to corrosion in atmospheres containing carbon dioxide and hydrogen sulfide and in oceanic atmospheres; In high temperature and high humidity air and contain organic acid atmosphere is small, galvanized layer is also easy to be corroded. There are many kinds of zinc plating solution, which can be divided into plating solution and no plating solution according to its properties. The galvanized liquid has good dispersion and covering property, the coating crystal is smooth and fine, the operation is simple, the application range is wide, and the long-term use is in the production. However, due to the toxic substances contained in the plating solution, the gas escaping from the plating process has great harm to the health of workers, and the waste water must be treated strictly before discharge.If the coating roughness is not caused by the above reasons, it may be caused by impurities in the plating solution. Can take a small amount of electroplating solution, after filtration test, then take a small amount of electroplating solution, after zinc powder treatment test, check the problem is caused by solid particles or copper, lead and other foreign metal impurities. Test them one by one and it’s not hard to find the cause of the problem. Galvanized iron wire coating foaming, binding force is not good.
Any application environment, users want a better the strength of the welded wire mesh, only need to improve its intensity, will make better the habit of using demand, but to be improved in the strength of this product, also need yo have a variety of conditions, will need to see factory in produce what kind of material, the strength of the product also is the material strength, But a manufacturer in the data does not fit the strength requirements, after all, there is no way to make the strength of the product progress, so this is the condition to.
This oxide film has greater elasticity and lubricity, does not affect the accuracy of parts. Therefore, the parts of precision instruments and optical instruments, spring steel, thin steel sheet, fine steel wire and so on are commonly bluing treatment. The commonly used galvanizing treatment of large roll galvanized wire is equivalent to forming a protective layer on the surface of the iron wire. The commonly used methods are hot dip galvanizing, hot spray plating, vacuum plating and so on. Different methods have corresponding characteristics.
Some customers are more concerned about quality problems, so for the service life is more important, barbed rope factory will generally recommend the use of high zinc barbed rope or stainless steel barbed rope.
3, reduce the bivalent iron ion in the plating aid used for hot plating wire, reduce the formation of zinc slag
Especially after passivation of galvanized layer, the surface of the oxide layer is thicker and compact, itself has high oxidation resistance. On the other hand, when the surface of the galvanized layer is damaged, exposing the inner iron matrix, because zinc is more active than iron, zinc will bear the role of sacrificing zinc anode, zinc will be oxidized before iron, so as to protect the iron layer will not be damaged. 2, line diameter, mesh spacing (refers to the edge of the twist to the opposite side of the distance).Now it is more used in the binding of the construction industry. Compared with ordinary wire, it is also softer and has better luster. Use in daily life does not need to carry out maintenance and maintenance, saving a lot of time, but also save the cost of maintenance and maintenance. Annealed wire has good stability, good corrosion resistance, greatly prolonging the service life. There are many kinds, which can be selected according to different uses. The device for making annealed wire is simple, and the utilization rate of the device is improved. The material properties of annealed wire can meet different processing needs.
Large coil galvanized wire in the zinc immersion distance debugging, keep the original speed unchanged, according to t= KD to determine the zinc immersion time (1), where: t is the zinc immersion time is constant, take 4-7D is the diameter of steel wire mm, and then estimate the zinc immersion distance. By adjusting the zinc dip distance, the zinc dip time of steel wire of various specifications can be shortened by 5s on average. In this way, the zinc consumption per ton of steel wire decreases from 61kg to 59.4kg.
The invention technology is used to put zinc block into the plating aid pool regularly, so that the bivalent iron in the plating aid becomes trivalent iron, and plays an important measure to stabilize the PH value within a numerical range, and also facilitate the filter filter out the trivalent iron ions in the plating aid; Ferric ion is controlled between 0.3 and 1.0g/L; When hydrogen is not released in the plating aid, the zinc block is continued. It is an effective measure to reduce zinc slag, improve the fluidity of zinc liquid and reduce the thickness of zinc layer to play the role of plating aid filter.
Dip plastic hook net disposal characteristics and downwind, dip plastic is also a common comparison, surface treatment color comparison is single, generally dark green, however, if you want to change into other colors, dip plastic will be more convenient. Because its inner line or inner tube is generally iron line, so, after a period of time, the inner line or inner tube will slowly corrode outward, compared to the outside of the glue fade, hook net will die.
Compared with other galvanizing processes, the cleaning requirements for low carbon steel wire before galvanizing are low. However, under the current trend of increasing the quality level of galvanized layer, some pollutants brought into the plating tank are obviously harmful. Because cleaning galvanized coating wastes a lot of time and reduces the production, it is very important to properly clean and effectively rinse the substrate before electroplating.