Galvanized hook mesh standard is thorough, mesh planning: 3cm-20cm, silk planning: 1.2mm-4.5mm, galvanized hook mesh 6000 square meters, some standards are available. Benefits: The selection of low carbon steel wire, surface for cold galvanized (electric galvanized) hot dip galvanized anticorrosion treatment, mesh wire strong, strong protection, long anticorrosion time.
In the calculation process of 12*14 specifications of barbed rope, it can not be calculated according to the above calculation formula, because first of all, two specifications of raw materials are used, the thinner the wire diameter, the higher the processing cost. Generally speaking, a kilogram of 12*14 barbed rope can reach about 7.5 meters, and the ratio of warp wire to barbed rope cannot be calculated according to the traditional ratio of 7 to 3. The exact amount of stinging and use the warp need to increase after a series of professional measurement on the loss of raw materials and so on factors to calculate.The bonding and anchoring function between cold wire drawing and cold rolled ribbed steel bar and concrete is outstanding. Therefore, when used in components, the phenomenon of cracking of component anchorage area and damage caused by steel wire slip is fundamentally eliminated, and the load-bearing ability and anti-cracking ability of component end are improved. In reinforced concrete structure, the crack width is smaller than that of circular steel bar or even that of hot rolled thread bar.
The lighting surface of each type of shed is designed to be curved, improving the Angle of the light surface, because the lighting surface is curved, no dust accumulation, good light transmittance, high temperature in the shed, after measurement, the average temperature in the shed is 3℃ higher than the traditional bamboo pole cement column shed, the yield is increased by 15~20%, and the harvest date is advanced. The formula is scientific, the surface does not absorb moisture, do not return halogen through modification technology and scientific production process, solve the greenhouse frame rod is easy to absorb moisture return halogen, poor water resistance and easy to change the shortcomings, so that the greenhouse steel pipe in the high temperature and high humidity environment, few drops, frost phenomenon, and reduce pests and diseases.
The reason why there are black spots in wire mesh welding is that the action of wire feeding should be timely filled in the melting time, and the development should be appropriate. There is no argon gas, long burning, large current, long distance, blunt tungsten needle and high molten pool temperature are the fundamental reasons for blackening. Continuous burning, is about active welding machine energy selection, machine welding will appear black spots.
Common galvanized iron wire equipment is usually used in barbecue net, barbecue net generally requires to have a long service life, with galvanized iron wire equipment to wire a layer of zinc, barbecue net is not easy to be corroded.
Hard black galvanized iron wire is made of low carbon steel wire directly drawn by drawing machine. The primary characteristics of hard black galvanized iron wire are high hardness and bright appearance. Primary use for welding hanger, umbrella, metal mesh, basket, basket and other metal products. Soft black galvanized iron wire is made of low carbon steel wire after annealing and softening, and then cold drawn. The primary feature of soft black galvanized iron wire is good flexibility, slightly higher hardness, bright appearance. Mainly used for metal mesh weaving process, electric welding mesh, welding process products.When using these two products, it is obvious that there is a gap between them. By pulling or bending the wire, it is often difficult to restore the original, for example, if the same place is repeatedly bent, it will be found that it has broken, and the cold drawing wire will not. Cold drawing wire compared with iron wire, its hardness, tensile resistance, bending ability is greatly enhanced, suitable for building materials.
Wire flexibility and elongation is good, can withstand the pressure of mechanical operation, in our country’s industry has played a very important role. There are many kinds of iron wire, the most common is to give black iron wire, galvanized iron wire. The corrosion resistance of the outer coating is effectively improved, but the phenomenon of crevice corrosion will be found after long-term use.
There are many kinds of zinc plating solution, which can be divided into plating solution and no plating solution according to its properties. The galvanized liquid has good dispersion and covering property, the coating crystal is smooth and fine, the operation is simple, the application range is wide, and the long-term use is in the production. However, due to the toxic substances contained in the plating solution, the gas escaping from the plating process has great harm to the health of workers, and the waste water must be treated strictly before discharge.The temperature of large roll galvanized wire should be controlled at 30 to 50℃ during electroplating. Because the chloride ions in the bath are very corrosive, quartz glass heaters are generally used. Continuous production does not need heating, but needs cooling. Cooling can be in the groove side row thin wall plastic pipe, through the flow of tap water cooling, can also be used as a titanium pipe temperature control device.
After proper heat treatment or cold drawing hardening, high carbon steel wire has high strength and hardness, high elastic limit and fatigue limit (especially notched fatigue limit), cutting function is acceptable, but welding function and cold plastic deformation ability is poor.
Remind you to buy galvanized iron wire, should be stored in dry, good ventilation conditions, do not contain corrosive gases, do not mix with the production of organic volatile gas paint, plastic and other substances in a good environment. If conditions, for galvanized parts to increase reliable inner packaging, and put desiccant. If the zinc layer white spots and hair, only mechanical removal, and then normal passivation, or thoroughly washed off the zinc layer after re-plating.